The Omni-Reactor Station " a perfect modular design"
With his unique modular design and just one base unit you can handle sample volumes in a rang from 2 ml up to 1 Liter! All heating blocks, glassware and reflux heads are interchangeable and the footprint is so compact that you can place the unit into any fume hood or onto any bench space. You will have a complete system working easy and fast for you! This is why:
Contact: René Harmsen
T:033-4571705 F:033-4571706
Postbus 496 3800 AL Amersfoort
Empty columns with 10 or 20um frit-phase separators and NaSO4
For fast and more precise temperature control. The temperature probe can be inserted either into a machined pocket in the reaction block or via a thermocouple pocket directly into one of the reaction vessels. The temperature sensor attaches directly into the Omni-Controller.
Omni Gas tight PTFE Caps™
By using a simple bi directional open/close lever each reaction vessel can be controlled separately. Each vessel cap has a septum to allow sampling at each vessel position.
Omni Reflux Head™
Efficient condensing and refluxing, for samples up to 25 ml is provided though the use of a liquid cooled aluminium reflux head. Cooling is introduced through the inlet/outlet ports. Individual reaction positions are numbered (1 - 10) for ease of tube and sample identification. A central gas inlet/outlet port combined with the gas-tight PTFE caps allow for a vacuum to be pulled and/or inert (nitrogen) to be ported into each individual tube.
Omni Reaction Vessels™
24mmx 150mm threaded glass reaction vessels; can handle volumes from 2 - 25 ml. Solutions can be added and removed through the top of the reaction vessel.
Omni Heater™
Encased reaction block ensures accurate temperature uniformity across the block. Unique patented air flow through ventilation slots beneath and around the rim of the case ensure a cool case temperature - allowing in to be safe to touch.
Omni-Cooling Plug™
Allows unit to cool down to -30 °C greatly expanding the types of chemistry you can perform with this equipment. The cooling plug is simple in use; insert the cooling plug into the reaction block, attach cooling lines to the inlet/outlet via quick disconnects. No longer a mess from melting ice.
Omni Controller™
Used to control both temperature and stirring speed. The Omni-Controller is easy to operate; Temperature and speed can be separately enabled to provide complete control of reactions. Both temperature and speed are individually adjustable by depressing the up/down keys. The control panel (on the controller) has three indicator lights; "Power on", "Heater on" and "Stirrer on" so you can closely view the performance of your system. A three digit display indicates actual temperature from -30 °C to 220 °C. Stirring speed is reflected by simple touching the stirrer speed knob.